A Glaucoma Survey.:Part 2 Follow-up Study Yoshimasa Isayama 1 , Kuniyoshi Mizokami 1 , Eiichi Hayashi 2 , Hideo Imamura 2 , Suteo Ogawa 3 , Hiroshi Goto 3 , Akio Yamanaka 4 1Department of Ophthalmology, Kobe University School of Medicine 2Nippon Steel Co., Hirohata Works 3Nippon Steel Co., Hirohota Hospital 4Kobe Kaisei Hospital pp.915-921
Published Date 1977/7/15
DOI https://doi.org/10.11477/mf.1410207469
  • Abstract
  • Look Inside

We have conducted mass screening for glau-coma covering 3,639 employees in an industrial establishment in Hirohata during the past 4 years. We conducted tonometry with standar-dized Schioez tonometer and funduscopy to de-termine the cup/disc ratio in subjects of more than 40 years of age. Persons with intraocular pressure of over 4.0/5.5g or cup/disc ratio greater than 2/3 were subjected to detailed ex-aminations. This second-step study could be made in 317 out of 321 thus selected subjects (98.8%). Glaucoma was diagnosed in 32 sub-jects (0.88%) and further 214 subjects were diagnosed as glaucoma suspect additionally.