雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Contamination of bottle containing antiglaucomatous ophthalmic solution without antiseptic additive Yasunori Yokoyama 1 , Yoko Goto 1 , Keiko Tanemoto 1 , Reiko Usuki 2 , Mamoru Saji 2 , Nobuhiro Ibaraki 1 1Dept of Ophthalmol,Chiba Hokusoh Hosp,Nippon Med Sch 2Dept of Pharmacy,Chiba Hokusoh Hosp,Nippon Med Sch pp.487-490
Published Date 2003/4/15
DOI https://doi.org/10.11477/mf.1410101178
  • Abstract
  • Look Inside

Abstract. We evaluated the risk of contamination of bottle containing timolol maleate,an antiglaucomatous agent. Twenty-one glaucoma patients were asked to use two ophthalmic solutions for one week each. One bottle contained timolol alone and the other contained timolol and benzalkonium chloride.Incubation of smears from the bottle neck showed bacteria in 8 samples from the former and in 12 samples from the latter. There was no significant difference in the rate of contamination between the two groups. We then examined the isolated organisms regarding the minimum inhibitory concentration(MIC)after addition of benzalkonium chloride. Gram-positive bacteria showed low MIC and gram-negative ones showed high MIC.The findings show that bottles containing timolol alone have a low risk of contamination after clinical use. Benzalkonium chloride has a limited antiseptic effect for gram-negative bacteria.


Copyright © 2003, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院