Laparoscopic inguinal hernia repair generally requires deployment of the operative field from only one access port other than the laparoscope and the cutting device, and it is often not easy to develop a flat surgical field to confirm the optimal dissecting layer reliably. We devised a “Hernia sac-traction method (HST method)”, which applied nylon thread to the dissected hernia sac and maintained continuous traction from the port on the affected side. Its sustained traction enable to facilitate good operative field deployment. Especially in the case of large external inguinal hernia, requiring strong traction of the hernia sac for dissection, this method provides reliable confirmation of the boundary of the hernia sac under good operative field. We believe that HST method enables stable and less stressful hernia surgery.