雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Clinical evaluation of Coburn refractive multifocal intraocular lens Nobuyuki Shoji 1 , Kimiya Shimizu 1 1Dept of Ohthalmol, Musashino Red Cross Hospital pp.1867-1873
Published Date 1995/12/15
DOI https://doi.org/10.11477/mf.1410908033
  • Abstract
  • Look Inside

We implanted Coburn refractive multifocal intraocular lens (IOL) in 53 eyes and evaluated the results in 48 eyes excluding 5 dropouts. Two models with different optic size were used: 68-STUV in 33 eyes and smaller P 359-TUV in 15 eyes. The former was followed up for 21.7 and the latter for 10.8 months. Corrected distance visual acuity (DVA) of 1.0 was obtained in 82% in the former and 87% in the latter. Near visual acuity (NVA) of 0.7 or better was obtained in 88% in the former and 93% in the latter. With or without distance correction, all the cases obtained DVA of 0.7 or better and NVA of 0.4 or better. The subjective impression of patients was better than 'good' and better than 'effective' in all. Adverse reactions were consistently absent. Postoperative astigmatism could be easily controlled, particularly in the latter type. It is assessed as clinically useful because of high incidence of good visual acuity for near and distance without correction.


Copyright © 1995, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院

関連文献

もっと見る

文献を共有