A case of secondary glaucoma due to intraocular ferrous foreign body Mizuho Tsuchiya 1 , Takashi Yanagida 1 , Masayuki Takahira 1 , Hisashi Kataguchi 1 , Masako Wada 1 1Div of Ophthalmol, Kanazawa National Hosp pp.956-957
Published Date 1991/6/15
DOI https://doi.org/10.11477/mf.1410900688
  • Abstract

A 39-year-old male had suffered from penetrat-ing injury by a ferrous foreign body in his left eye 5 years before. His visual acuity was reduced to hand movement with intraocular pressure of 72 mmHg. The foreign body was encapsulated and was located in the inferior nasal periphery of the vitreous. Gonioscopic findings were normal.Electroretinogram showed reduced but not extin-guished oscillatory potential, a- and b waves. The foreign body was removed by vitrectomy and intraocular magnet. It weighed 0.5 mg and proved to be of stainless steel, martensite group, from microchemical analysis. It appeared that the electroretinogram was still recordable because the foreign body was encapsulated and was of non-corrosive stainless steel.


Copyright © 1991, Igaku-Shoin Ltd. All rights reserved.