A case of unilateral deuteranopia.:1. Measurement of the spectral sensitivities of the three cone mechanisms by Wald's selective adaptation method Osamu Okajima 1 , Michika Okamoto 1 , Tetsuma Ozawa 2 1Department of Ophthalmology, Faculty of Medicine, University of Tokyo 2Department of Ophthalmology, Tokyo-Teishin Hospital pp.1091-1095
Published Date 1982/9/15
DOI https://doi.org/10.11477/mf.1410208705
  • Abstract
  • Look Inside

A 20-year-old female manifested typical findings of deuteranopia in her right eye and nearly normal color vision in her left eye. The deuteranopia in the right eye was diagnosed by positive findings by various pseudoisochromatic plates, Farnsworth-Munsell 100-hue test and Nagel anomaloscope. The left eye was judged as normal by the same ex-aminations except by the Ishiraha test. Her father was deuteranopic.

Spectral sensitivities of the three cone mecha-nisms were measured by the Wald's selective adap-tation method in normal subjects, a group of deu-teranopes and both eyes of this patient.


Copyright © 1982, Igaku-Shoin Ltd. All rights reserved.