雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Intraocular Pressure during General Anesthesia Hajime Nakatani 1 , Masaoki Nakauchi 1 , Kazumi Maeda 1 , Yukio Kubota 2 , Saburo Sasai 2 , Masahiro Ohara 2 , Yasuko Inoue 3 1Department of Ophthalmology, Osaka Kosei Nenkin Hospital 2Department of Anesthesiology, Osaka Kosei Nenkin Hospital 3Kosaki Hospital pp.811-815
Published Date 1975/7/15
DOI https://doi.org/10.11477/mf.1410205324
  • Abstract
  • Look Inside

Repeated measurements of intraocular pres-sure were conducted in 41 normal eyes (21 sub-jects) during general anesthesia, using : OF (Halothane & O2), GOF (Halothane, N2O & O2), GOE (Ether, N2O & O2) or GOP (Methoxyflu-rane, N2O & O2). Tonometry was done with handheld applanation tonometer (Perkins) and was repeated at the interval of approximately 3 minutes for 18 minutes after induction of general anesthesia.

The intraocular pressure started to decrease after induction of general anesthesia and was stabilized 6 to 12 minutes after induction.