雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

A model of opaque cornea in the pig eye for practice of cataract surgery Satoru Joko 1 1Dept of Ophthalmol,Musashino Red Cross Hosp pp.465-469
Published Date 2010/4/15
DOI https://doi.org/10.11477/mf.1410103135
  • Abstract
  • Look Inside
  • Reference

Abstract. Purpose:To report a model of opaque cornea in the porcine eye for practice of cataract surgery. Material and Method:Corneal opacity was produced by applying diathermy in excised pig eye. Cataract surgery was practiced on this model. Results:It was possible to produce corneal opacity either in the superficial,stromal or deep layer within a few minutes. Surgical manipulation could be practiced on this model with poor visibility of the anterior chamber. Conclusion:Opaque cornea of any type and any shape could be produced with this method. It promises to be of value in the practice of cataract surgery on eyes with cloudy cornea.


Copyright © 2010, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院

関連文献

もっと見る

文献を共有