雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Oxygen therapy with masks or cannulas for spontaneously breathing patients Masahide OHTSUKA 1 1Department of Intensive Care Medicine Yokohama City University Medical Center pp.423-432
Published Date 2018/4/1
DOI https://doi.org/10.11477/mf.3102200516
  • Abstract
  • Look Inside
  • Reference

For low-flow oxygen therapy, the appropriate device should be selected based on the required fraction of inspired oxygen (FIO2) for an individual patient. Nasal cannulas, simple facemasks, and reservoir masks are indicated for patients who require an FIO2 of 0.4 or less, 0.35 thorough 0.60, and 0.6 or more, respectively. Although the FIO2 can be adjusted by oxygen flow rates, FIO2 may significantly depend on the tidal volume or ventilatory patterns of each patient. Nasal cannulas, which do not add mechanical dead space, may be suitable for patients with impaired elimination of carbon dioxide. For high-flow oxygen therapy, Venturi masks are often used, while a Venturi device with jet nebulizer and heater should be selected for a patient who requires active humidification. Proper application of these devices with sufficient oxygen flow is a key for optimal high flow oxygen therapy.


Copyright © 2018, MEDICAL SCIENCES INTERNATIONAL, LTD. All rights reserved.