雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

HYDRODYNAMIC STUDLES ON THE METHOD OF CYSTOMETRY Seigi Tsuchida 1 , Takashi Morita 1 , Osamu Yamaguchi 1 pp.39-43
Published Date 1977/1/20
DOI https://doi.org/10.11477/mf.1413202287
  • Abstract
  • Look Inside

Hydrodynamic characteristics of the retrograde cystometry was examined.

The measured pressure through the inserted catheter was always higher than the intravesical pres-sure. This defference (measured-intravesical) bacame more evident when the perfusion rate of the fluid was increased and the size of the inserted catheter was decreased. It was concluded that this error was inevitable as long as the same route was utilized for both the perfusion of fluid and the measurement of the pressure. The use of a double lumen catheter was more beneficial than the previous method in the retrograde cystometry.


Copyright © 1977, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1332 印刷版ISSN 0385-2393 医学書院

関連文献

もっと見る

文献を共有