雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Corneal shape and thickness after overnight wearing of disposable soft contact lens Yasuo Tanaka 1 1Tanaka Eye Clinic pp.191-195
Published Date 1994/2/15
DOI https://doi.org/10.11477/mf.1410903624
  • Abstract
  • Look Inside

Corneal curvature and thickness were measured in 10 persons after overnght wearing of disposable hydrogel contact lens in the right eye only. The values in the left eye served as control. The cases were all females. The ages ranged from 19 to 27 years, average 22.4 years. The corneal thickness in the left eye increased by 1 to 27μm, average 16μm. This value accounted for 2.9% of corneal thickness the previous day. The corneal thickness in the right eye increased by 23μm to 72μm, average 50μm. This value accounted for 9.5% of the conreal thickness. There were no significant changes in the corneal curvature between both eyes. Above findings suggest the inherent danger of continuous wearing of disposable contact lens.


Copyright © 1994, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院