Studies on automated display system for pseudoisochromatic plates. 5. Improvement in the method of presentation with a summary of the whole study Kaitiro Hukami 1 1Dept of Ophthalmol, Fukui Med Sch pp.1507-1509
Published Date 1992/10/15
DOI https://doi.org/10.11477/mf.1410901330
  • Abstract
  • Look Inside

We developed an automated display system of pseudoisochromatic plates to standardize the test conditions. We could reduce the size of the proto-type by introducing Tokyo Medical College Color Vision Test, TMC plates, which require lesser read-ing distance. Shortening of presentation to 0.4 sec-ond resulted in less false negative responses.

We attached a ten-key system as method of inputby the examinee as the final improvement to the system. The present system has various advan-tages. The test results would be more reliable than by conventional procedures because of exact test conditions and random order of presentation of plates. Further, color-defective examinees can be tested confidentially and are freed from the uneasi-ness when they make false answers.