Refractive error and individual A constant of the new intraocular lens SS-60YG Toyohiro Tsumura 1 , Hiroyuki Nomoto 2 , Hidetaka Yamaji 3 1Department of Ophthalmology, Takamatsu Municipal Hospital Kagawa Clinic 2Nomoto Eye Clinic 3Shirai Hospital pp.973-979
Published Date 2016/6/15
DOI https://doi.org/10.11477/mf.1410211853
  • Abstract
  • Look Inside
  • Reference

Abstract Purpose: To report the refractive error and individual A constant of the new intraocular lens(IOL)SS-60YG.

Cases and Method: This study was made on 92 eyes of 53 patients who received cataract surgery during the past 10 months. The power of inserted IOL ranged from +17 to +27 diopters. Refraction was measured during surgery, the following day, 7 to 10 days, one and 3 months after surgery. Findings were compared with another series of 411 eyes implanted with NS-60YG.

Results: Means of refractive error in SS-60YG showed no difference with NS-60YG during surgery, the following day, 7 to 10 days, one and 3 months after surgery(p=0.097〜0.985, t-test). Personal A constant of the lenses were 118.72(SS-60YG)and 118.67(NS-60YG). Individual A constant in SS-60YG ranged from 118.46 to 118.94. This value showed no significant difference from that of NS-60YG(p=0.263, t-test).

Conclusion: The refractive error and individual A constant of SS-60YG was no significant difference compared with NS-60YG.


Copyright © 2016, Igaku-Shoin Ltd. All rights reserved.