Results of the Binkhorst 2 loop lens implantation and evaluation of lens fixation Okihiro Nishi 1 , Kyoko Uemura 1 , Motoko Nishi 1 , Hisako Hosokawa 1 1Nishi Eye Hospital pp.713-718
Published Date 1982/7/15
DOI https://doi.org/10.11477/mf.1410208635
  • Abstract
  • Look Inside

We performed intraocular lens implantation sur-gery with the use of Binkhorst iridocapsular lens in 48 eyes during the past 21-month period. Luxation of the lens occurred in 2 eyes (4%) and could be corrected surgically. The implanted lens was fixed with the lens capsules in 44 eyes (92%) and was not fixated in 4 eyes. The non-fixation was recog-nized by the lens movement with the pupil reac-tion when illuminated under slitlamp observation. Topical miotic treatment had to be continued in these four eyes.

Topical miotics therapy had to be performed in all case for at least 3 days after surgery.


Copyright © 1982, Igaku-Shoin Ltd. All rights reserved.