Transscleral sulcus fixation of foldable single-piece acrylic intraocular lens Yasuyo Oya 1 , Naoichi Horio 1 , Atsuhiro Tanikawa 1 , Masayuki Horiguchi 1 1Dept of Ophthalmol,Fujita Health Univ Sch of Med pp.2089-2093
Published Date 2006/12/15
DOI https://doi.org/10.11477/mf.1410101595
  • Abstract
  • Look Inside
  • Reference

Abstract. Purpose:To evaluate foldable single-piece acrylic intraocular lens(IOL)for transscleral sulcus fixation. Cases and Method:This retrospective study was made on 15 aphakic eyes of 15 cases that received implantation of foldable single-piece acrylic IOL(VA-65,HOYA)through a 3.5mm corneal incision during the past 9 months. Results:Visual acuity remained unchanged or improved in all the cases. The IOL was fixated in the center of the pupil area immediately after implantation. There was no complication throughout during the follow-up averaging 8.4 weeks. Conclusion:Implantation and sulcus fixation of single-piece acrylic IOL(VA-65)through small corneal incision appears to be safe and useful.


Copyright © 2006, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院

関連文献

もっと見る

文献を共有