雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Limit of the reversibility of the left ventricular function after aortic valve replacement for aortic regurgitation Kanji Kawachi 1,2 , Soichiro Kitamura 1,2 , Hajime Hirose 1 , Susumu Nakano 1 , Choken Oyama 1,2 , Kei Sakai 1 , Toshiyuki Hiranaka 1 , Kazuhiro Taniguchi 1 , Shigeo Koh 1,2 , Tohru Mori 1,3 , Yasunaru Kawashima 1 1The 1st Department of Surgery, Osaka University Medical School pp.729-732
Published Date 1984/7/15
DOI https://doi.org/10.11477/mf.1404204482
  • Abstract
  • Look Inside

Twelve patients underwent aortic valve replace-ment with Bjork-Shiley tilting disc valve prosthesis for aortic regugitation. Pre and post-operative left ventricular function was evaluated.

There were nine patients with ejection fraction higher than 0.35 (G-I) and three patients lower than it (G-II). In G-I, the left ventricular volume (LVESV, LVEDV) and the left ventriular mass decreased significantly after surgery and the ejection fraction returned to normal value. In G-II, the left ventricular volume and the left ventricular mass decreased, however, they were abnormally high values and the ejection fraction decreased after surgery.

The left ventricular function is considesed to be fully reversible postoperatively, if values of LVEDV, wall thickness and LV mass are lower than 350 ml/m2 of LVEDV, 1.5cm of wall thickness and 350g/m2 of LV mass.


Copyright © 1984, Igaku-Shoin Ltd. All rights reserved.