雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Mitral and Aortic Valve Replacement and Tricuspid Valve Repair in a Patient with Metal Allergy Toshimichi Nonaka 1 , Kazuki Kato 1 , Mayumi Kamada 1 , Masayoshi Tokoro 1 , Motoshi Kosakai 1 , Takahisa Sakurai 1 , Hajime Sakurai 1 1Department of Cardiovascular Surgery, Chukyo Hospital Keyword: metal allergy , prosthetic valve replacement , patch test pp.578-582
Published Date 2021/8/1
DOI https://doi.org/10.15106/j_kyobu74_578
  • Abstract
  • Look Inside
  • Reference

We report a 63-year-old woman came to our hospital with exertional dyspnea, palpitations, and abdominal distention. Echocardiography showed mitral, aortic, and tricuspid valve insufficiency, for which surgery was indicated. Twenty-six years ago, during dental therapy, she was diagnosed with metal allergy. A patch test demonstrated allergic reactions to manganese, chromium, and zinc. The patient underwent mitral and aortic valve replacement with the On-X prosthetic heart valve, which is primarily made of titanium and devoid of the allergens. She also underwent tricuspid valve repair with a Contour 3D annuloplasty ring, which is made of titanium alloy. She manifested no allergic symptoms three years after surgery. This case elucidates the importance of history taking regarding metal allergy and identification of allergens by patch testing in patients undergoing cardiac surgery involving metal device implantation.


© Nankodo Co., Ltd., 2021

基本情報

電子版ISSN 2432-9436 印刷版ISSN 0021-5252 南江堂