An modified N-shaped folding of three-piece silicone intraocular lens Susumu Tohsaka 1 , Hidenori Kubodera 1 , Takuma Yuguchi 1 , Tadayoshi Kaiya 1 , Koshi Maeda 2 , Shigeru Kinoshita 2 1Dept of Ophthalmol Seirei Hamamatsu Hosp 2Dept of Ophthalmol Kyoto Prefectural University of Medicine pp.1127-1130
Published Date 1995/6/15
DOI https://doi.org/10.11477/mf.1410904358
  • Abstract
  • Look Inside

We modified the method of insertion of foldable three-piece silicone intraocular lens (IOL) with a high refractive index. The N-shaped folding was performed with two instruments of blunt lens holder and Fine folder without using the lens case as the folding stand. This method enabled the folding of IOL under the surgical microscope and contributed to shortening the duration of surgery.