雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Profile of seventy-three corneas that remained transparent ten years after keratoplasty Chikako Kimura 1 , Masao Matsubare 2 , Tsutomu Sato 2 , Mitsuru Sawa 3 , Teruo Tanishima 4 1Dept of Ophthalmol Toshiba Chyuo Hosp 2Dept of Ophthalmol Tokyo Univ Fac of Med 3Dept of Ophthalmol Section of Corneal Transplantation, Tokyo Univ Fac of Med 4Dept of Ophthalmol Hibiya Eye Clinic pp.999-1002
Published Date 1990/7/15
DOI https://doi.org/10.11477/mf.1410900249
  • Abstract
  • Look Inside

We evaluated 73 eyes with clear corneal graft with a minimum follow-up of 10 years. We took following factors into evaluation: age of the donor, the condition that necessitated keratoplasty, frequency of episodes of graft rejection, number ofpast grafting and mean size of the donor endoth-elial cells.

There was no correlation between the longterm graft survival and donor age or frequency of rejec-tion. The nature of the host disease, number of past grafting and mean cell size were positively correlat-ed with the graft survival. The mean endothelial cell size increased gradually to 1,300μm2 for 7 postoperative years. The cell size showed wide variations among individual cases. The average cell size decreased thereafter to become stable at around 1,000μm2 after 9 years.