Fine thread method and filter paper method for measuring lacrimation Katsuaki Kurihashi 1 1Department of Ophthalmology, Faculty of Medicine, Kyoto University pp.1101-1107
Published Date 1978/7/15
DOI https://doi.org/10.11477/mf.1410207707
  • Abstract
  • Look Inside

A new tear test using fine cotton thread, 0.25 mm in diameter was devised. This test takes only five seconds, compared Schirmer's first method which takes five minutes. I made criteria for a tentative diagnosis of degree of lacrimal deficiency in the three consecutive measurement of this test for patients without lacrimal drainage dysfunction as follows:

Stage 1 (possible lacrimal deficiency) : I ) less than 1.00 in ratio (diseased side/normal side: d/n) in all of the three consecutive measurements.


Copyright © 1978, Igaku-Shoin Ltd. All rights reserved.