  • Look Inside

The apparatus for ophthalmophacometry, by which the first and second Purkinje-Sanson images were photographed, was used for mea-suring the posterior curvature radius of the cornea.

In order to determine the best optical arran-gement of the light source and the accuracy of this measurement, experimental and theoretical studies were performed using four artificial model corneas. It was found that the best op-tical position of the light source was at the angle of 20° from the optical axis of the camera lens.