雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Electrophysiological Evaluation of Human Consciousness Level by "Automated Fluctuation Analysis" of Human High Frequency EEG Munetomo Nakata 1 , Jiro Mukawa 1 , Kunimasa Nerome 2 , Seitetsu Hokama 2 1Department of Neurosurgery University of the Ryukyus, School of Medicine 2Department of University of the Ryukyus, School of Medicine Keyword: automated fluctuation analysis , high frequency EEG , fast Fourier transform , Lorentzian fluctuation , consciousness level pp.1087-1093
Published Date 1992/12/1
DOI https://doi.org/10.11477/mf.1406900417
  • Abstract
  • Look Inside

This study is done to clarify the clinical meaning of "Automated Fluctuation Analysis" of high fre-quency EEG in man especially focused on the fine alteration of consciousness level of the subjects.

Twenty normal volunteers were utilized for this study. They were divided into two groups, the subjects who felt sleepiness (Group S ; N = 8) and the subjects who denied it (Group W ; N =12) , during the EEG recording.

"Automated Fluctuation Analysis" of high fre-quency EEG had been presented in our previouspaper. In short, it is made of three steps, amplification of EEG signal, A/D conversion and Fast Fourier Transform by signal processor and extraction of Lorentzian parameters. Power spec-tral density (PSD) was displayed on log-log graph. Then the third step is performed by the best curve fitting program to the following equation, S (f) = S1/ [1+(f/fc1) 2] +S2/ [1+(f/fc2) 2], where S (f) is power spectral density at any frequency f, S1 and S2 are plateau level of initial and second Lorentz, respectively and fc, and fc2 are the corner or half power frequency of initial and second Lorentz, respectively. The algorithm of this program to extract these parameters were mathematically based on Brown & Dennis.

As results, 1. PSD of human high frequency EEG was composed of double Lorentzians and vanished into white level within 1kHz. 2. A topographical display of S1 value revealed hyperfrontal in group W, which is in accordance with the cerebral blood flow study by Ingvar. This pattern disappeared in group S. 3. There was statistical significances about S2 value between two groups, which strongly sug-gests the second Lorentz reflects the fine alteration of subcortical activation system. 4. "Automated Fluctuation Analysis" enabled us to manipulate EEG very simply and reliably.


Copyright © 1992, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 2185-405X 印刷版ISSN 0006-8969 医学書院

関連文献

もっと見る

文献を共有