A Case of Accidental Penetration of a Pre-placed Central Venous Catheter Ryoji GOTO 1 , Kazuo NAKANISHI 2 , Taro FUJITANI 2 , Naoki ABE 1 , Tasuku NISHIHARA 1 , Toshihiro YOROZUYA 1 1Department of Anesthesia, Ehime University Hospital 2Department of Anesthesia, Ehime Prefectural Central Hospital Keyword: central venous catheter , guideline , ultrasound-guided puncture , x-ray fluoroscopic puncture pp.253-256
Published Date 2024/4/10
DOI https://doi.org/10.18916/masui.2024040010
  • Abstract
  • Look Inside
  • Reference

 We report the accidental puncture of a previously placed central venous catheter(CVC)during the insertion of a temporary pacing lead.

 The patient underwent transcatheter aortic valve replacement under general anesthesia and a CVC was inserted under ultrasonic(US)guidance. During the surgical procedure, the patient required temporary pacing and the right internal jugular vein was punctured under US guidance. The guidewire penetrated the CVC.

 Although guidewires are visible on US, CVCs are invisible. When performing a puncture near a CVC, we recommend using fluoroscopy in addition to US guidance.