Clinical Application of High Resolution Computed Tomography of Temporal Bone Diseases Jin Kanzaki 1 1Department of Otolaryngology, School of Medicine, Keio University pp.993-1001
Published Date 1981/11/20
DOI https://doi.org/10.11477/mf.1492210428
  • Abstract
  • Look Inside

 Using CT/T 8800 with high spatial resolution, target imaging of the various temporal bone diseases was performed. Coronal and axial scans were made. Target imaging is an effective means of studying patients with cholesteatomas, semicircular canal fistula, diseases of the internal auditory canal (acoustic neuroma, or stenosis) and inner ear anomaly (hypoplasia, or distension of the vestibulum).

 The results of the comparison of CT and polytomography of the temporal bone were as follows: 1. In most cases, the pathological process was demonstrated with CT scans better than or same as with polytomograms. 2. The radiation dose of CT scan is low. 3. The axial images of the temporal bone were easily obtained with CT. 4. CT is more effective than polytomography in the diagnosis and evaluation of the temporal bone involved by tumor and cholesteatoma, especially attic cholesteatoma. 5. In cases with temporal bone fracture, acoustic neuroma or other intracranial diseases, contrast-enhanced CT can be done.


Copyright © 1981, Igaku-Shoin Ltd. All rights reserved.