Studies on Testing Methods for Astigmatism: I. Line Chart Method vs. Cross Cylinder Method Sukeyuki Oshima 1 , Masuko Takagaki 1 1Dept. of Ophthalmology, Tokyo Medical and Dental University pp.1147-1152
Published Date 1966/8/15
DOI https://doi.org/10.11477/mf.1410211127
  • Abstract
  • Look Inside

The astigmatic errors determined by the line chart test and the cross cylinder test werecompared for 115 eyes, and the following re-sults were obtained.

The amount and the axis of the astigmatism measured by the both methods coincided in only 23 eyes (20.0%), while the visual acuity with the correction determined by the both metheds coincided in 88 eyes (76.5%), The reason why the discrepancy happened was discussed.