A case of an intraocular foreign body reaching deep into the choroid with only minor impact Daizo Matsumoto 1 , Yusuke Arai 1 , Rika Tsukii 1 , Kosuke Nagaoka 1 , Shinichi Sakamoto 1 , Hidenori Takahashi 1 , Hidetoshi Kawashima 1 1Department of Ophthalmology, Jichi Medical University pp.1152-1156
Published Date 2023/9/15
DOI https://doi.org/10.11477/mf.1410214905

閲覧方法のご案内

この論文を閲覧するためにはログインが必要になります。
パスワードを忘れた場合 新しくユーザー登録する 施設共通IDをご利用の方はこちらから

PPV購入案内

1,320円 (1,200円+税10%) こちらは、1152ページから1156ページの文献です。
PPV(ペイ・パー・ビュー)とは、論文(記事)単位で購入・閲覧ができるサービスです。
購入には医書.jp本会員登録が必要です。



会員登録完了後に改めて上記「購入サイトへ」を選択してください。
または「購入サイトへ」選択後に「購入ログイン」、「新規会員登録」の順に進んでください。

会員登録について詳しくはをご確認ください。
  • Abstract
  • Look Inside
  • Reference

Abstract Purpose:To report a case of an intraocular foreign body(metal fragment)that penetrated deep into the choroid with only minor impact.

Case:A 21-year-old man complained of slight ocular pain in the right eye after a minor impact with an object in a warehouse.

Findings and Clinical Course:On initial examination, the visual acuity of the right eye was 0.9, and the intraocular pressure in the right and left eye was 16 mmHg and 17 mmHg respectively. A shallow anterior chamber and conjunctival edema were evident in the right eye, with a tear in the cornea at 7 o'clock. The fundus showed subretinal white lesions and preretinal and subretinal hemorrhage. Although no obvious perforation or intraocular foreign body was observed, an intraocular foreign body was suspected based on computed tomography. Subsequently, a choroidal tear extending to a white lesion near the macula was confirmed through vitrectomy. Examination of the white lesion revealed no intraocular foreign body, and the procedure was completed with silicone oil replacement. Postoperative computed tomography showed persistent intraocular foreign body in the eye, and the patient underwent reoperation. The white lesion was thoroughly examined deeper into the choroid, and the foreign body was located and removed with forceps. The retrieved foreign body was a cylindrical metal fragment, 3 mm in length.

Conclusion:Even a minor impact with an object can cause a foreign body to penetrate deep into the choroid, and come cases may require a deeper search of the choroid for a foreign body.