The effects of waiting time after clamp of a linear automatic stapling instrument in small bowel resection of a pig Katsuhiko MORITA 1 , Kazuhisa TOKUNOU 1 , Sakurao HIRAKI 1 , Akitoshi KUDO 1 , Shintarou FUKUDA 1 , Masaaki OKA 2 1Department of Surgery, UBE Industries, LTD. Central Hospital 2Department of Surgery Ⅱ, Yamaguchi University School of Medicines Keyword: 器械縫合 , 動物実験 , 待ち時間 pp.461-463
Published Date 2006/8/15
DOI https://doi.org/10.11477/mf.4426900727
  • Abstract
  • Look Inside

Backgroud and Methods: To determine the necessity for the waiting times between clamping and firing a linear stapler, we evaluated the number of bleeding points in anastomotic sites (N=6) and the ratio of dry tissue weight to wet tissue weight (DW ratio) (N=20) using the pig small intestine cut with linear staplers. Two groups consisted of No Wait group (a linear stapler was fired immediately after clamping) and the Wait group (a linear stapler was fired one-minute after clamping).