The anterior chamber angle following posterior chamber lens implantation Eiichi Shoji 1 , Mikiko Miyakura 1 , Shinichiro Yoshida 1 , Noriyuki Sato 1 , Yoshitaka Obara 1 1Dept of Ophthalmol, Koshigaya Hosp Dokkyo Univ, Sch of Med pp.1771-1775
Published Date 1991/11/15
DOI https://doi.org/10.11477/mf.1410900940
  • Abstract
  • Look Inside

We evaluated the gonioscopic features after im-plantation of posterior chamber lens in 74 eyes. There were differences in the incidence of periph-eral anterior synechia (PAS) and pigment disper-sion depending on the type of surgery and loop fixation. PAS was more frequent along the 10 to 2 o'clock position. Pigment dispersion tended to bepresent from 4 to 8 o'clock area.

Elevation of intraocular pressure over 21 mmHg occurred in 4 of 74 eyes, 5%. Facility of outflow was decreased to less than 0.15 in 5 eyes, 7%, 6months after surgery. All these eyes manifested pathological gonioscopic features including PAS and pigment dispersion.


Copyright © 1991, Igaku-Shoin Ltd. All rights reserved.