雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Evaluation of suture materials for cataract surgery Toshine Maeda 1 , Yasuo Takenaka 2 , Hisayuki Tsuchisaka 3 1Dept of Ophthalmol, Kyorin Univ Sch of Med 2Dept of Ophthalmol, Asahi General Hosp 3Dept of Ophthalmol, Tokyo Women's Med Col, Daini Hospital pp.503-505
Published Date 1988/5/15
DOI https://doi.org/10.11477/mf.1410210369
  • Abstract
  • Look Inside

We evaluated the role of different suture mate-rials in the amount of corneal astigmatism after conventional extracapsular cataract extraction (ECCE), when performed by relatively inexperi-enced surgeons.

Either of the three ophthalmology residents per-formed ECCE in 31 eyes following a set protocol : four-plane, 120°-incision, manual nucleus extrac-tion and cortex aspiration, and 5 interrupted sutures. The suture material was randomly selected from a choice of : 8-0 polyglycolic acid (PGA), 9-0PGA and 9-0 silk. The postoperative corneal astig-matism and conjunctival irritation around the sutures were evaluated over a follow-up period of 3 months.

The postoperative course and final amount of corneal astigmatism was independent of which suture material was used for surgery. As a minor difference, 8-0 PGA was slightly more irritating than the other two.

The findings show that the surgical procedure for ECCE as described above is a suitable one for relatively inexperienced surgeons. The choice of suture material does not significantly affect the postoperative corneal astigmatism.

Rinsho Ganka (Jpn J Clin Ophthalmol) 42(5) : 503-505, 1988


Copyright © 1988, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1308 印刷版ISSN 0370-5579 医学書院