雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

COMPUTED TOMOGRAPHIC MEASUREMENT OF REGIONAL CEREBRAL BLOOD FLOW BY XENON ENHANCEMENT Hiromu Segawa 1 , Norio Yoshimasu 1 , Osamu Nakamura 1 , Koichi Aritake 1 , Susumu Wakai 1 , Kintomo Takakura 1 , Yasuichi Ueda 2 , Kazumoto Kimura 2 , Akira Tamura 3 , Keiji Sano 3 1Department of Neurosurgery, University of Tokyo Hospital 2Department of Neurosurgery, Dokkyo University School of Medicine 3Department of Neurosurgery, University of Teikyo Hospital pp.291-297
Published Date 1982/3/1
DOI https://doi.org/10.11477/mf.1406204913

閲覧方法のご案内

この論文を閲覧するためにはログインが必要になります。
パスワードを忘れた場合 新しくユーザー登録する 施設共通IDをご利用の方はこちらから

PPV購入案内

1,320円 (1,200円+税10%) こちらは、291ページから297ページの文献です。
PPV(ペイ・パー・ビュー)とは、論文(記事)単位で購入・閲覧ができるサービスです。
購入には医書.jp本会員登録が必要です。



会員登録完了後に改めて上記「購入サイトへ」を選択してください。
または「購入サイトへ」選択後に「購入ログイン」、「新規会員登録」の順に進んでください。

会員登録について詳しくはをご確認ください。
  • Abstract
  • Look Inside

The present study was conducted to overcome some of disadvantages of cerebral blood flow study by radionuclide, such as poor regionality of flow values and errors involved in pathological brains.

Serial CT scanning was carried out during and after inhalation of 50 to 70% non-radioactive xenon in humans. Diffusible gas with high atomic number enhanced gray matter first 19±4 HU (mean±SD) on an average in Hounsfield unit (HU) and later white matter 24±4 HU. In seven normal subjects, blood flow in gray matter was 82±11 and that in white matter 24±5 ml/100 gm/min. Partition coef-ficient which is not readily obtainable by radio-nuclide study was 0.9±0. 1 in normal gray matter and 1.4±0.2 in normal white matter.

Two cases were presented to show k-map (clear-ance rate), 2-map (partition coefficient) and CBF map, which displayed images of values calculated automatically, in black and white or color on CRT. The first case was a patient with metastatic brain tumor from lung in the left parietal region. The blood flow of the tumor was close to that of gray matter, whereas blood flow of edematous white matter surrounding the tumor was decreased to below 10ml/100g/min with partition coefficient ranged from 0 to 0.9. The second case was pres-ented to demonstrate the resolution of the blood flow map obtained by this method. Multiple lacunar infarcts of the basal ganglia and white matter in the size of 1 to 3 mm, which were hardly identified on regular CT picture, were well visualized on CBF map.

This method appeared to have several advantages over conventional isotope method and to provide useful clinical and research informations.


Copyright © 1982, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 2185-405X 印刷版ISSN 0006-8969 医学書院

関連文献

もっと見る

文献を共有