A new rneasurement of pulmonary venous compliance by R-synchronized volume loading Toshihisa Asakura 1 , Toshio Mitsui 1 , Jun Miya 1 , Hidehiro Nakajima 1 , Motokazu Hori 1 1Department of Surgery, Institute of Clinlcal Medicine, University of Tsukuba pp.985-991
Published Date 1987/9/15
DOI https://doi.org/10.11477/mf.1404205122

閲覧方法のご案内

この論文を閲覧するためにはログインが必要になります。
パスワードを忘れた場合 新しくユーザー登録する 施設共通IDをご利用の方はこちらから

PPV購入案内

1,320円 (1,200円+税10%) こちらは、985ページから991ページの文献です。
PPV(ペイ・パー・ビュー)とは、論文(記事)単位で購入・閲覧ができるサービスです。
購入には医書.jp本会員登録が必要です。



会員登録完了後に改めて上記「購入サイトへ」を選択してください。
または「購入サイトへ」選択後に「購入ログイン」、「新規会員登録」の順に進んでください。

会員登録について詳しくはをご確認ください。
  • Abstract
  • Look Inside

It is known that pulmonary venous system, which consists of the pulmonary veins and left atrium plays an important role for the upstream vascular capacity of left heart system and pulmonary venous compliance (Cpv) indicates a function of vascular capacity. In spite of the importance of Cpv, there are few appropriate methods to measure Cpv due to a difficulty in approaching the pulmonary venous sys-tem. Therefore, we designed a direct and simple measurement of Cpv by R-synchronized volume load-ing during the open-heart operation and evaluated its utility experimentally.

In 12 anesthetized open-chest dogs, a balloon (volume=ΔV) was inserted in the left atrium through the left auricle. Pulmonary venous pressure (PVP) wave measured with a low pressure transducer in-dicated v wave during mitral valve closure. Elevated pressure (ΔP) from control v wave was measured when the balloon (ΔV=3~10ml) was inflated during mitral valve closure at the rate of one time per two beats using Model 20-AVCO in a synchro-nized fashion.

PVP along with volume loading (JV) standardized by body weight was plotted on a regression line with a statistical significance (r =0.98±0.02). Cpv obtained from this slope was concluded to be 0. 146 ±0.056ml・mmHg-1・ kg-1 when PVP was 8.8±2.1 mmHg and Cpv developed a tendency to decrease as PVP increased.

We designed a new method of pulmonary venous compliance measurement by R-synchronized volume loading, and the utility of our method is charac-terized by the prevention of leakage of loading volume to the ventricle and by the variableness of loading volume. Cpv was concluded to be in a state of static compliance, because it indicated the almost constant value to loading volume change. Cpv obtained with our method was 0.146±0. 056 mi.mmHg-1・kg-1, which was almost the same as proposed in previous reports.