Noncontact corneal aesthesiometer Mayumi Kajikawa 1 , Keizou Takahashi 1 , Shigehisa Maeoka 1 , Toshihiko Uno 1 , Yuichi Ohashi 1 , Hitoshi Hayashi 2 1Dept of Ophthahnol, Ehime Univ Sch of Med 2Dept of Ophthalmol, Saiseikai Matsuyama Hosp pp.861-864
Published Date 1995/5/15
DOI https://doi.org/10.11477/mf.1410904303
  • Abstract
  • Look Inside

We developed a noncontact corneal aesthesiometer by modifying a noncontact tonometer. It showed a high reliability in repeated measurements in normal volunteers. It showed a high correlation in corneal sensitivity values with Cochet-Bonnet corneal aesthesiometer. The corneal sensitivity was higher in 18 young persons (mean age: 23.7) than in 23 aged persons (mean age: 61.9). The threshold value of corneal sensitivity in 23 diabetic persons (mean age: 61.9) was higher by 40% than in aged-matched healthy persons. It was also higher by 30% in 9 contact lens wearers (mean age: 22.9) than in aged-matched healthy persons. The present apparatus thus shows a high reliability in obtained values under variable but constant air stimulation, and an accurate target orientation by realtime monitoring.


Copyright © 1995, Igaku-Shoin Ltd. All rights reserved.