A new operationmethod of Exenteratio bulbi Shogo Hiwatari 1 1Depart. of Ophthalmology, Nippon Medical School pp.286-288
Published Date 1960/2/15
DOI https://doi.org/10.11477/mf.1410206845
  • Abstract
  • Look Inside

I considered a new operationsmethod of Exenteratio bulbi, that is after the 1/4 cutting of the all length of sklera and conjunctiva bulbi far from the limbus of cornea about 10 mm, made the exenteration of the bulbus, putted in the plastik-ball of 16~20mm of the diameter, and used a thin eye prothese. And then I could succeed to get the nice appearance and good eye-prothese's movement.