Intraocular lens implantation using Healon V and air: Report 2 Takeo Onishi 1 , Noriko Okada 1 , Ryohei Koide 2 1Dept of Ophthalmol,Ohta-Atami Hosp 2Dept of Ophthalmol,Showa Univ Sch of Med pp.1409-1414
Published Date 2004/8/15
DOI https://doi.org/10.11477/mf.1410100677
  • Abstract
  • Look Inside

 We performed cataract surgery on 40 eyes using 3 techniques after phacoemulsification-aspiration. In 20 eyes,silicone intraocular lens(IOL)was inserted using Healon V(R)which was later removed by behind-the-lens procedure(BTL group). In 10 eyes,IOL was inserted using small amount of Healon V and air. Healon V was removed by Rock'n Roll procedure(R&R group 1). In 10 eyes,IOL was inserted using moderate amount of Healon V and air. Healon V was removed by Rock'n Roll procedure(R&R group 2). Intraocular pressure(IOP)24 hours after surgery was significantly lower in R&R group 1 than in the other two groups. IOP 4 hours after surgery was higher than 30mmHg in 2 eyes of BTL group,in none of R&R group 1 and in one eye of R&R group 2. Postoperative rise in IOP may be avoided by using small amount of Healon V and air during IOL insertion.


Copyright © 2004, Igaku-Shoin Ltd. All rights reserved.