Treatment with DDD Pacemaker for Complete Atrioventricular Block in an Adult Patient with Corrected Transposition of the Great Arteries Akihiro Kanda 1 , Ichiro Watanabe 1 , Yukie Takahasi 1 , Kazuhiko Kondo 1 , Toshiaki Kojima 1 , Kazuhira Hibiya 1 , Satoshi Saito 1 , Yukio Ozawa 1 , Tadao Yasugi 1 1The Second Department of Internal Medicine, Nihon University School of Medicine Keyword: 完全房室ブロック , 修正大血管転位症 , DDDペースメーカー , complete atrioventricular block , corrected transposition of great arteries , DDD pacemaker pp.69-73
Published Date 1994/1/15
DOI https://doi.org/10.11477/mf.1404900801
  • Abstract
  • Look Inside

A 44-year-old man with a history of dyspnea on mild effort was found to have complete atrioventricular block (CAVB) on routine ECG. Holter ECG showed that the mean heart was 46/min (maximum heart rate; 67 beat/min, minimum heart rate; 30 beat/min). He was admitted to the hospital and shown to have correct-ed transposition of the great arteries (C-TGA) associat-ed with tricuspid regurgitation and aortic regurgitation. The diagnosis was proved by echocardiography, chest magnetic resonance imaging (MRI), cardiac catheriza-tion and angiography.


Copyright © 1994, Igaku-Shoin Ltd. All rights reserved.