A case of spigelian hernia repaired by laparoscopic surgery with Composix Kugel Patch Katsutaka WATANABE 1 , Takanori KYOKANE 1 , Yoshitaka TOYODA 1 1Department of Surgery,Fukuroi Municipal Hospital Keyword: スピーゲルヘルニア , 腹腔鏡下手術 , コンポジックスクーゲルパッチ pp.691-695
Published Date 2013/11/15
DOI https://doi.org/10.11477/mf.4426101015
  • Abstract
  • Look Inside
  • Reference

A 68-year-old man was referred to our hospital because of a painful palpable mass over his left lower abdomen. Abdominal ultrasonography and CT revealed bowel prolapsing at the lateral edge of rectus abdominal muscle. Based on the preoperative diagnosis of spigelian hernia (SH), laparoscopic repair of the hernia was performed. The peritoneum surrounding the defect was dissected circumferentially and 2-0 nylon threads were used to fix the Composix Kugel Patch® to the preperitoneal space. The peritoneal flaps were stitched together with running sutures. The postoperative course was uneventful and the patient was discharged on postoperative day 3. This is the first report of SH repair with Composix Kugel Patch® by laparoscopic surgery in Japan. Composix Kugel Patch® includes a shape-memory ring. It facilitates the procedures under laparoscopic surgery and may be useful for laparoscopic SH repair.


Copyright © 2013, JAPAN SOCIETY FOR ENDOSCOPIC SURGERY All rights reserved.