Percutaneous Revision of Shunt with Obstructed Ventricular Catheter Hirohisa ONO 1 , Tadayoshi MORIYAMA 1 , Keiki UNEOKA 1 , Hidekatsu MATSUMURA 1 , Yuzo FUJITA 1 , Masahiro YONEKURA 1 , Kazuo MORI 1 1Department of Neurological Surgery, Nagasaki University School of Medicine Keyword: Percutaneous shunt revision , Cerebrospinal fluid shunt pp.365-370
Published Date 1976/4/10
DOI https://doi.org/10.11477/mf.1436200439
  • Abstract
  • Look Inside

Shunt dysfunction due to an obstructed ventricular catheter can be avoided, at least in part, by placing the of the catheter anteriorly to the Foramen of Monro. Howevre, once the catheter is obstructed, surgical removal under general anesthesia is almost inevitable. Irrigation method for an obstructed ventricular catheter enables us to gain scarcely anything and accumulation of instilled fluid in the vetnricle often causes the dangerously increased intracranial pressure.

1) Technique for placement of the ventricular catheter.