雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Prevention of Flexor Pollicis Longus Tendon Rupture after Volar Plating for Distal Radius Fractures Shunro OKAMOTO 1 , Kaoru TADA 1 , Ai HACHINOTA 1 , Kazuo IKEDA 1 , Fumio HASHIMOTO 1 , Hiroyuki TSUCHIYA 1 1Department of Orthopaedic Surgery, Graduate School of Medical Sciences, Kanazawa University Keyword: 橈骨遠位端骨折 , distal radius fracture , 長母指屈筋腱断裂 , flexor pollicis longus tendon rupture , 予防 , prevention pp.925-928
Published Date 2014/10/25
DOI https://doi.org/10.11477/mf.1408200020
  • Abstract
  • Look Inside
  • Reference

 Background:Flexor pollicis longus (FPL) tendon rupture has been highlighted as a complication after volar plating for distal radius fractures. We reviewed 8 cases of FPL tendon rupture and assessed the validity of our policy of recommending hardware removal in "tendon irritation sign" cases.

 Methods:We evaluated 28 wrists all of which had been treated for a distal radius fracture with the Acu-Loc® distal radius plate system (ACUMED LLC, USA).

 Results:The "tendon irritation sign" was positive in 22 of the 28 wrists. We intra-operatively diagnosed frayed tendons in 7 wrists. The sensitivity of the "tendon irritation sign" for frayed FPL tendons was 100%, and its specificity was 28.6%.

 Conclusions:Evaluation for the "tendon irritation sign" was useful as a means of preventing flexor pollicis longus tendon rupture.


Copyright © 2014, Igaku-Shoin Ltd. All rights reserved.