雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Surgical Experience of Total Arch Replacement Using Frozen Elephant Trunk, for Type B Acute Aortic Dissection Takashi Ando 1 , Hiroshi Goto 1 , Kazuma Date 1 , Hiroshi Okada 1 , Makoto Takeda 1 1Department of Cardiovascular Surgery, Yokohama Rosai Hospital Keyword: Stanford type B acute aortic dissection (BAD) , frozen elephant trunk (FET) , median sternotomy , entry closure pp.989-994
Published Date 2018/11/1
DOI https://doi.org/10.15106/j_kyobu71_989
  • Abstract
  • Look Inside
  • Reference

Recently, advanced technique and device of thoracic endovascular aortic repair (TEVAR) enabled surgical intervention for type B acute aortic dissection (BAD). However, BAD have often serious complications;cerebral infarction, spinal cord infarction, multi-organ ischemia or necrosis, and retrograde type A acute aortic dissection. TEVAR is performed for complicated BAD for the aim of life saving in such a failure case of conservative treatment.

Here we reported our surgical experience of total arch replacement using frozen elephant trunk (FET) by median sternotomy, for BAD with failed conservative treatment. There are 3 advantages;brain protection using selective cerebral perfusion, main entry closure using FET, and prevention of retrograde type A acute aortic dissection following prosthetic graft replacement. We examined how to select a FET product size and described operative procedures.


© Nankodo Co., Ltd., 2018

基本情報

電子版ISSN 2432-9436 印刷版ISSN 0021-5252 南江堂

関連文献

もっと見る

文献を共有