A CASE OF RENAL FOREIGN BODY STONE ORIGINATED FROM THE POLYMER:COATING OF GUIDEWIRE Risaku Kawaguchi 1 , Takayuki Matsui 1 1Urology, Aijinkai Chibune Hospital Keyword: 腎結石 , 異物 pp.71-72
Published Date 1992/1/20
DOI https://doi.org/10.11477/mf.1413900518
  • Abstract

A 40-years-old male patient consulted our hospital complaining of the left lumbago. He underwent left percutaneous nephrolithotomy at another hospital 3 years before. X-ray examinations showed a soybean-sized foreign body stone originated from the hydrophilic polymer coating of guidewire (RADIFOCUS®) used and left in the lower area of the left kidney at the previus operation. We treated a patient with extracorporeal shock wave lithotripsy (ESWL). Stone and foreign body were disintegrated, and 1 month later after ESWL plain X-ray film showed no stone and foreign body.


Copyright © 1992, Igaku-Shoin Ltd. All rights reserved.