術後合併症なく経過した圧迫性頚髄症患者37名を対象に10秒テストの再テスト信頼性を検証した.術後6カ月と12カ月でJOAスコアに有意な変化はなく,神経症状は一定と仮定した.術後6カ月の10秒テストは右26.0±6.1,左25.7±5.9,術後1年で右25.9±5.8,左26.4±5.9であり,級内相関係数は0.74~0.84で,再テスト信頼性は高かった.健常者に比較すると多数回検査(慣れ),治療意欲などの理由により頚髄症患者における10秒テスト再現性は高いものと考えられた.
We investigated the test-retest reliability of the 10-second test in 37 cervical myelopathy patients without postoperative complications enrolled in the study. Their neurological status was the same at 6 months postoperatively and 12 months postoperatively according to the Japan Orthopaedic Association (JOA) scores. Medical records were reviewed for the results of the 10-second test and showed that at 6 months postoperatively they were 26.0±6.1 on the right and 25.7±5.9 on the left and that at 12 months postoperatively they were 25.9±5.8 on the right and 26.4±5.9 on the left. The intraclass correlation coefficients ranged from 0.74 to 0.84, indicating that the test is highly reliable. The results showed that the 10-second test is a reliable test for use in cervical myelopathy patients, who undergo frequent examinations and have a more cooperative attitude toward examinations than healthy volunteers.
Copyright © 2007, Igaku-Shoin Ltd. All rights reserved.