雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Retrieval of Migrated Microcatheter with Retrieval Forceps during Cerebral Aneurysm Embolization: A Case Report Kentaro HAYASHI 1 , Naoki KITAGAWA 1 , Minoru MORIKAWA 2 , Yoichi MOROFUJI 1 , Kazuhiko SUYAMA 1 , Izumi NAGATA 1 1Department of Neurosurgery,Nagasaki University School of Medicine 2Department of Radiology,Nagasaki University School of Medicine Keyword: cerebral aneurysm , embolization , microcatheter , disruption , retrieval forceps pp.485-490
Published Date 2009/5/10
DOI https://doi.org/10.11477/mf.1436100941

閲覧方法のご案内

この論文を閲覧するためにはログインが必要になります。
パスワードを忘れた場合 新しくユーザー登録する 施設共通IDをご利用の方はこちらから

PPV購入案内

1,320円 (1,200円+税10%) こちらは、485ページから490ページの文献です。
PPV(ペイ・パー・ビュー)とは、論文(記事)単位で購入・閲覧ができるサービスです。
購入には医書.jp本会員登録が必要です。



会員登録完了後に改めて上記「購入サイトへ」を選択してください。
または「購入サイトへ」選択後に「購入ログイン」、「新規会員登録」の順に進んでください。

会員登録について詳しくはをご確認ください。
  • Abstract
  • Look Inside
  • Reference

 Endovascular embolization for a cerebrovascular lesion has been increasingly performed. We experienced disruption of the microcatheter during a cerebral aneurysm embolization and removed the catheter fragment with retrieval forceps. A 56-year-old woman was brought to our hospital because of consciousness disturbance. Radiological examination revealed subarachnoid hemorrhage due to the rupture of an anterior communicating artery aneurysm. Despite endovascular embolization and neck clipping of the aneurysm, the aneurysm recurred. Then, endovascular embolization was performed. During introduction of the microcatheter to the cerebral aneurysm, the microcatheter disrupted spontaneously at the center of the catheter and the distal end of the catheter migrated into the right middle cerebral artery. The proximal part of the catheter fragment was located at the common carotid artery bifurcation. An attempt to retrieve the catheter by snare failed. Then, retrieval forceps were navigated. The catheter fragment was caught at the common carotid artery bifurcation and successfully removed. Subsequently, the cerebral aneurysm was embolized with detachable coils. No additional complication occured. Microscopical observation of the catheter end revealed relatively sharp disruption and extension of the stainless steel blade. Microcatheter disruption and migration is a rare but significant complication of endovascular embolization. Percutaneous technique with retrieval forceps for the extraction of intravascular foreign objects was useful.


Copyright © 2009, Igaku-Shoin Ltd. All rights reserved.

基本情報

電子版ISSN 1882-1251 印刷版ISSN 0301-2603 医学書院

関連文献

もっと見る

文献を共有