雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Successful Intraoperative Use of Intra-aortic Balloon Pumping for a Transcatheter Aortic Valve Implantation in a Patient with Severe Aortic Stenosis and Low Cardiac Function in whom Extracorporeal Circulation through the Femoral Artery is Hesitated Yosuke TANIMURA 1 , Motoi TAKEUCHI 1 , Tatsuro YOKOYAMA 1 , Koshiro KIKKAWA 1 , Hiroha SHIBATA 1 , Ryohei ITO 1 1Department of Anesthesiology, Ogaki Municipal Hospital Keyword: transcatheter aortic valve implantation(TAVI) , intra-aortic balloon pumping(IABP) , aortic stenosis pp.754-759
Published Date 2023/8/10
DOI https://doi.org/10.18916/masui.2023080011
  • Abstract
  • Look Inside
  • Reference

 In transcatheter aortic valve implantation(TAVI)for aortic stenosis, there are cases in which low cardiac function prevents maintenance of circulatory function during the procedure, especially after rapid pacing. In such cases, there are reports of TAVI using veno-arterial extracorporeal membrane artificial lung(V-A ECMO), but few reports of TAVI with intra-aortic balloon pumping(IABP). In this report, we describe a case in which TAVI was performed safely and effectively with IABP in a patient with severe aortic stenosis and low cardiac function.