Buckle-sutured polyester thread intrusion into the vitreous three years after retinal detachment surgery Kazunori Takubo 1 , Bijohira Ichirou 1 , Yuji Okamoto 1 , Kazutaka Kani 1 , Takayuki Sotani 1Dept. of Ophthalmol, Hyogo Coll of Med pp.517-519
Published Date 1987/5/15
DOI https://doi.org/10.11477/mf.1410210033
  • Abstract
  • Look Inside

A 59-year-old female was treated for rheg-matogenous retinal detachment in her left eye. The retina could be reattaced using silicone sponge exoplants. Encircling procedure was performed with 2.5 mm sponge, meridian buckling with 3.0 mm sponge and radial buckling.

One year after surgery, a part of the meridian sponge slipped out of bulbar conjunctiva and had to be removed. Three and half a year after surgery, a 5-0 polyester thread fixating the silicone spongewas found to have intruded into the vitreous perforating the choroid and retina. While this intru-sion did not incur untoward consequences, due precaution seemed to be necessary in future detach-ment surgical procedures to avoid such incidents.

Rinsho Ganka (Jpn J Clin Ophthalmol) 41(5) : 517-519・987