雑誌文献を検索します。書籍を検索する際には「書籍検索」を選択してください。

検索

書誌情報 詳細検索 by 医中誌

Japanese

Devices for Transvenous Embolization of Dural Arteriovenous Fistulas Masafumi HIRAMATSU 1 , Jun HARUMA 1 , Kenji SUGIU 1 , Shota TANAKA 1 1Department of Neurological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences Keyword: デバイス , 経静脈的塞栓術 , 硬膜動静脈瘻 , アプローチ , 塞栓物質 , device , transvenous embolization , dural arteriovenous fistula , approach , embolic material pp.149-156
Published Date 2026/1/10
DOI https://doi.org/10.11477/mf.030126030540010149
  • Abstract
  • Look Inside
  • Reference

 When approaching an occluded sinus during transvenous embolization of dural arteriovenous fistulas, it is important to employ a combination of appropriate guiding and distal access catheters to ensure adequate support and effective navigation. When navigating a long and tortuous venous route, careful attention must be given to the backup support and lengths of the coaxial catheters and connectors. Effective embolization can be achieved by selecting coils according to the stage of the embolization procedure and using liquid embolic agents when indicated.


Copyright © 2026, Igaku-Shoin Ltd. All rights reserved.